Recirculating vs. Ducted Range Hoods and Ventless Dryers in New NYC Condos
Short answer: Most new NYC condo plans route kitchen air outside, but not all. 22% of the 573 offering plans that describe the range hood specify a recirculating hood, one that filters the air and blows it back into the room. That rises to 36% in buildings with 100 or more apartments. Dryers are split almost evenly: 51% of the 1,229 plans that name the dryer type specify ventless dryers.
Three Ways a Plan Handles Kitchen Air
Offering plans describe kitchen ventilation in one of three ways:
- Ducted hood (33% of plans). The hood has its own fan and a duct that goes outside, either through a wall or into a riser up to the roof.
- Shared building exhaust (45%). The plan says the kitchens are exhausted through the building's risers and roof fans, but often doesn't describe a hood at all. Only 20% of these 256 plan sentences mention a hood. Many describe a small exhaust grille in the kitchen ceiling. Air leaves the apartment, but you may still have a recirculating hood over the stove.
- Recirculating hood (22%). Also called ductless. A fan pulls air through a grease filter and usually a charcoal filter, then returns it to the kitchen. It catches some grease and odor. It doesn't remove heat or moisture.
The recirculating share hasn't moved in one direction over time. It has ranged between 16% and 32% in every filing period we tracked:
| Year plan was filed | Plans (hood) | Recirculating hood | Ducted or shared exhaust | Plans (dryer) | Ventless dryer |
|---|---|---|---|---|---|
| Before 2015 | 149 | 24% | 74% | 159 | 33% |
| 2015–2018 | 116 | 16% | 84% | 223 | 45% |
| 2019–2021 | 145 | 24% | 76% | 353 | 53% |
| 2022–2023 | 60 | 32% | 68% | 211 | 54% |
| 2024–2026 | 103 | 17% | 83% | 283 | 63% |
Share of plans that describe the range hood, and of plans that name the dryer type, by the year the plan was first filed. "Ducted or shared exhaust" counts ducted hoods and kitchens exhausted through the building's shared risers. 2026 is the year so far.
Bigger Buildings Recirculate More
Building size is the clearest dividing line. In buildings under 10 apartments, 16% of the 237 plans specify recirculating hoods. In buildings of 100 or more, it's 36% of 76. In a small building, the kitchen is often a few feet from an outside wall or a short run from the roof. In a tower, each hood duct has to run through ceilings and shafts to reach a riser.
| Under 10 apartments | 16% |
|---|---|
| 10–29 apartments | 21% |
| 30–99 apartments | 28% |
| 100+ apartments | 36% |
Share of plans that describe the range hood. Building size is the number of residential units in the plan.
Condo Book Researchcondobooknyc.com/research/recirculating-vs-ducted-range-hoods-ventless-dryers-nyc-condos
By borough, Manhattan (26% of 232 plans) and Brooklyn (23% of 251) are close. Queens plans recirculate less often (12% of 83).
A gas stove doesn't guarantee a ducted hood. Among plans that also name the cooktop fuel, 24% of the 403 with gas cooktops specify recirculating hoods. That's about the same as electric and induction kitchens (22% of 85). Gas burners give off combustion gases and moisture as well as cooking smoke, so this pairing is the one to check for if you cook a lot. See gas vs. induction stoves in new NYC condos.
Ventless Dryers: Now the Majority
A vented dryer pushes hot, damp air outside through a duct. A ventless dryer keeps it inside. A condenser dryer cools the air to pull the water out. A heat pump dryer does the same while reusing the heat, so it uses less energy. Either way, the water drains away or collects in a tray.
Ventless dryers have gone from the minority to the majority. Of the plans filed before 2015 that name the dryer type, 33% specified ventless (of 159 plans). For plans filed 2024–2026, it's 63% (of 283).
Size matters here too. 44% of the 680 plans for buildings under 10 apartments specify ventless dryers, against 68% of the 95 plans with 100 or more. Queens is the most ventless borough (67% of 118 plans), ahead of Manhattan (53%) and Brooklyn (49%). For hookups vs. included machines, see washer/dryers in new NYC condos.
Where vented dryers go. Of the 314 vented-dryer plans that say where the duct runs, 72% mention a riser, a shaft or the roof. The other 28% say only that it goes through a wall or to the outside.
Heat pump or condenser? Most plans just say "ventless." Only 21% of the 632 ventless plans name one type or the other. Among those that do, heat pump dryers went from 4% of plans filed before 2019 (of 51) to 25% since (of 81). The rest named condenser dryers. These counts are small, so treat them as a direction, not a precise share.
The two choices go together. Buildings that recirculate the kitchen usually skip the dryer duct too: 72% of the 90 plans with recirculating hoods that name a dryer type specify ventless dryers, against 46% of the 268 with ducted or shared exhaust.
Examples From the Plans
- Malabar Residences in Manhattan (145 apartments) specifies recirculating hoods in all kitchens and ventless dryers.
- 757 Flatbush Avenue in Brooklyn (132 apartments) also pairs recirculating hoods with ventless dryers.
- 267 Bainbridge in Brooklyn shows small buildings do it too: 7 apartments, recirculating hoods, ventless dryers.
- The Morgan in Manhattan (137 apartments) runs kitchen exhaust through shared-riser ductwork, with ventless dryers.
- 140 Jane Street in the West Village (15 apartments) has ducted hoods and vented dryers.
Some buildings mix types by apartment. At 80 Clarkson, hoods are ducted except in the studios, which recirculate. At The Gild on West 54th Street, hoods are recirculating except in the penthouses. Our count records one value per plan. At least 5 plan sentences say outright that some apartments differ, so check your unit.
Tips for Buyers
- Search the plan's building description for "kitchen exhaust," "range hood" and "recirculat." The appliance schedule often lists the hood model, sometimes with "(vented)" or "(recirculating)" next to it.
- If the plan only mentions "common exhaust" or "risers," ask whether your hood is ducted into them or only the ceiling grille is.
- A recirculating hood's charcoal filter needs regular replacement. Ask for the model so you know which filter to buy.
- With a ventless dryer, expect longer cycles and some warmth in the closet. Check whether it drains to a pipe or has a tray you empty.
- If you're buying your own dryer for a hookups-only closet, check whether the closet has a vent. If not, you'll need a ventless model.
- A ducted hood or dryer vent usually can't be added later. Running a new duct through an exterior wall or shared shaft typically needs building approval.
Search "condos with vented range hood" or "condos with ventless dryer" on The Condo Book Project.
How This Is Counted
We read the range hood sentence in 573 NYC condo offering plans and the dryer type in 1,229. Each plan gets one value per item. A "ducted hood" plan says the hood connects to a duct, a riser or the outside. A "shared building exhaust" plan describes kitchen exhaust through common risers or roof fans without saying the hood is connected. A "recirculating" plan says the hood is recirculating or ductless. Dryers are vented or ventless as the plan states. Heat pump and condenser dryers are counted only when a plan sentence names them. Plans are grouped by the year they were first filed with the New York Attorney General, and by the number of residential units. Percentages are of plans that describe the item. Bronx and Staten Island plans count in the totals but have too few to report separately. Updated October 2026.
FAQ
Do new NYC condos have vented range hoods?
Most plans send kitchen air outside. 22% of NYC condo plans that describe the hood specify a recirculating one. The rest have a ducted hood or kitchen exhaust through the building's risers, though riser plans don't always say the hood itself is connected.
Why do some condos use recirculating hoods?
Running a separate duct from every kitchen to the outside is harder in a big building. 36% of plans for buildings with 100+ apartments specify recirculating hoods, against 16% in buildings under 10.
Can you have a gas stove with a recirculating hood?
It happens. 24% of the plans that specify gas cooktops also specify recirculating hoods. If you cook often on gas, check the plan for a ducted hood.
Are ventless dryers common in NYC condos?
Yes. 63% of the plans filed since 2024 that name the dryer type specify ventless dryers, up from 33% before 2015.
Is a heat pump dryer the same as a ventless dryer?
A heat pump dryer is one kind of ventless dryer. The other is a condenser dryer. Heat pump models use less energy but usually run longer. Most offering plans just say "ventless" without naming the type.
Can I add a vent for my dryer or hood later?
Usually not on your own. A new duct has to go through an exterior wall or a shared shaft, which typically needs the condo board's approval. Check the plan before you buy.
Related: Do New NYC Condos Include a Washer/Dryer? · How NYC Condo Finishes Changed Since 2010