Energy-Efficient Condos in NYC: Which New Buildings Have the Best Ratings
Short answer: The most efficient condos aren't always the ones that advertise it. The most efficient apartment heat pump we found in an NYC offering plan is rated 30.5 SEER, at 803 Quincy Street in Brooklyn. The best-insulated windows have a U-factor of 0.15, at the Dovecote in Harlem. For context, the typical plan filed since 2020 that states a rating lists about 18 SEER and windows at 0.30. Below are the buildings at the top and what each rating means.
The Numbers That Make a Building Energy-Efficient
"Eco-friendly" on a listing doesn't tell you much. The offering plan's description of the building does, because it lists the equipment and often its rated efficiency. These are the numbers to look for:
- SEER (cooling efficiency). How much cooling a heat pump or air conditioner delivers per unit of electricity over a season. Higher is better. Newer plans may say SEER2, a stricter test that gives somewhat lower numbers for the same unit; the SEER figures in this article leave SEER2 ratings out.
- HSPF (heating efficiency). The same idea for heating. Higher is better.
- EER (peak cooling efficiency). Efficiency on a hot day at full load. It always reads lower than SEER, so don't compare one with the other.
- COP (coefficient of performance). Heat delivered per unit of electricity. A COP of 3 means three units of heat for every one you pay for. Plans use it for big central heat pumps and heat pump water heaters.
- U-factor (windows and walls). How much heat gets through. Lower is better. A window's U-factor matters most, because glass loses far more heat than an insulated wall.
- R-value (insulation). How well a wall or roof resists heat flow. Higher is better.
447 NYC condo plans filed since 2020 state a SEER (not counting SEER2), and 242 state a window U-factor. Many plans state neither, so a missing number doesn't mean a building is inefficient. It just means you have to ask.
The Most Efficient Heat Pumps
Many new NYC condos now heat and cool with electric heat pumps (see how new NYC condos heat and cool). Ratings vary a lot. These plans give the highest SEER for the equipment that actually serves the apartments:
| Building | SEER | What it serves | Plan page |
|---|---|---|---|
| 803 Quincy Street Brooklyn | 30.5 / 26.1 | Mitsubishi ductless wall units in each room (smaller / larger rooms) | p. 219 |
| 1601 55th Street Brooklyn | 27.2 | The air conditioning units in each apartment | p. 147 |
| 2929 Brighton 5th Street Brooklyn | 24.6 / 23.1 | Mitsubishi air handlers in the apartments; HSPF about 10 and 11 | p. 140 |
| Dovecote Manhattan | 19.7 | Fujitsu heat pumps, 10.5 HSPF; Passive House pre-certified | p. 161 |
| Lexe Brooklyn | 17.7 | LG heat pumps, 9.5 HSPF; designed to Passive House | p. 205 |
The SEER each offering plan gives for the equipment that heats and cools the apartments, on the plan page shown. Higher is more efficient.
- 803 Quincy Street in Brooklyn puts an inverter-driven Mitsubishi ductless unit in each room: 30.5 SEER in the smaller rooms and 26.1 in the larger ones.
- 1601 55th Street, a 3-unit building in Brooklyn, rates its apartment units at 27.2 SEER.
- 2929 Brighton 5th Street lists Mitsubishi air handlers at about 24.6 and 23.1 SEER, with heating at about 10 and 11 HSPF.
Notice that the buildings with the most insulated envelopes, the Dovecote, Lexe and 28 Herbert Street (Williamsburg Green), don't top this list. Their heat pumps sit at 17.7 to 19.7 SEER. A tight, well-insulated building needs less heating and cooling to begin with, so a mid-range heat pump does the job. A high SEER in a leaky building can still use more electricity than a lower SEER in a tight one.
Brands matter less than the model and rating. See HVAC brands in NYC condos for which makers show up most.
The Best-Insulated Windows
Windows are the weak spot in any wall. The typical plan filed since 2020 that gives a window U-factor lists 0.30. These plans list much lower:
| Building | U-factor | The windows | Plan page |
|---|---|---|---|
| Dovecote Manhattan | 0.15 | Yaro, 50mm triple-glazed (average) | p. 140 |
| Alchemy Queens | 0.18 | Cortizo aluminum with thermal breaks; doors 0.14 | p. 153 |
| 185 Skillman Avenue Brooklyn | 0.18–0.28 | Silhouette triple-glazed, aluminum frame with thermal break | p. 199 |
| 842 Sixth Avenue Manhattan | 0.19 | Triple-pane, argon-filled | p. 242 |
| 200 West 88th Street Manhattan | 0.206 | Argon-filled insulated glass with a noise-reducing laminate | p. 270 |
The window U-factor each offering plan gives, on the plan page shown. Lower lets less heat through.
- The Dovecote at 11 West 126th Street uses Yaro tilt-and-turn windows with 50mm triple-glazed glass. Its plan says the building is pre-certified to the Passive House Institute US standard.
- Alchemy in Long Island City uses thermally broken Cortizo aluminum windows at 0.18, and terrace doors at 0.14.
- 185 Skillman Avenue in Brooklyn specifies triple-glazed Silhouette windows from 0.18 to 0.28, depending on the window.
- 842 Sixth Avenue in NoMad, with 94 homes, is the largest building in the window table. It uses triple-pane, argon-filled glass at 0.19.
Triple glazing also blocks street noise. See soundproofing in NYC condos, and who replaces condo windows.
Fresh Air and Hot Water
A tight building has to bring in fresh air on purpose. The efficient way is an energy recovery ventilator (ERV), which warms or cools the incoming air with the outgoing air. Lexe in Crown Heights puts a Zehnder ComfoAir ERV in a closet in each apartment, and its plan rates the units at 96% efficiency. 28 Herbert Street in Williamsburg gives the same 96% for its Ventacity units. Read more in do new NYC condos have ERVs.
Hot water is the other big load. More new buildings heat it with heat pumps instead of gas. Lexe's Sanden heat pump water heaters list a COP of 2.8; VITA's, below, list 4.11, the highest hot water COP in this article. See hot water heaters in NYC condos. And an all-electric building usually means an induction kitchen; see gas vs. induction.
A Large Building That States More: VITA
VITA, 122 homes in two buildings at 489 and 501 Ninth Avenue in Hell's Kitchen, is the largest building in this article, and its plan states several ratings. It uses Mitsubishi heat-recovery VRF heat pumps, with a COP of about 3.42 and an EER of about 10.5 (p. 212); those are peak-condition figures, not comparable with the SEER table above, and the plan gives no SEER. Hot water comes from heat pump water heaters rated at a COP of 4.11 (p. 212). The walls are rated R-20 (p. 199); the plan gives no window U-factor. Its Schedule B-1 engineer's estimate puts a 624-square-foot one-bedroom's electricity at about $811 a year (p. 88). The plan doesn't claim a green certification. More is in the VITA buyer's guide.
How to Check a Building's Efficiency Claims
- Find the right rating. A plan's highest SEER is often for a small unit in the elevator machine room or lobby. Read which equipment serves the apartments.
- Watch for "or approved equal." Most plans let the sponsor swap in other equipment. 2929 Brighton 5th Street's plan says the sponsor may use heat pumps from a different maker. Ask what was actually installed.
- Look for Schedule B-1. Many plans include an engineer's estimate of each apartment's yearly energy cost. It's the closest thing to an energy label.
- Check the windows first. Triple glazing and a U-factor well below the typical 0.30 usually mean the whole wall was taken seriously.
- Ask about fresh air. An in-apartment ERV is the most efficient way to ventilate; windows-only is the least.
- Certification claims need a disclaimer check. Several Manhattan plans say the sponsor makes no guarantee the building will comply with Local Law 97 or be certified as Passive House. Read the risk section.
Search the plans on The Condo Book Project for "triple glazed," "heat recovery" or "energy recovery" to find more.
How This Is Counted
We searched the text of every NYC condo offering plan for SEER, HSPF, EER, COP and U-factor ratings, then read the page around each high rating to keep only the ones for equipment serving the apartments and for windows (not doors, skylights or walls). Each figure in this article is checked against the plan page cited at every build. The typical figures cover plans in the five boroughs first filed with the New York Attorney General since 2020: for each plan, the median of the ratings it states, then the median plan. Ratings are what the plans specify; the finished building can differ, and many plans don't give ratings at all.
FAQ
What is the most energy-efficient condo in NYC?
No single number settles it. 803 Quincy Street has the highest apartment heat pump rating we found, at 30.5 SEER. The Dovecote has the best-insulated windows, at a U-factor of 0.15. Among large buildings, VITA and 842 Sixth Avenue state more efficiency detail than most.
What is a good SEER rating for a NYC apartment?
The typical NYC condo plan filed since 2020 that states one lists about 18 SEER. The top plans list 24.6 to 30.5. But insulation and windows matter as much as the heat pump.
What is a good window U-factor?
Lower is better. The typical recent plan that states one lists 0.30. Triple-glazed windows in the best buildings list 0.15 to 0.19.
Is VITA an energy-efficient building?
Its plan describes heat-recovery VRF heat pumps, heat pump water heaters with a COP of 4.11, R-20 walls, fiberglass window frames and induction kitchens. The engineer projects about $811 a year in electricity for a 624-square-foot one-bedroom. The plan doesn't claim a green certification.
Do eco-friendly condos cost less to run?
They usually use less electricity, but your bill depends on rates and how you live. Check the plan's Schedule B-1 for the engineer's yearly estimate for your apartment type.
Where do these figures come from?
From the efficiency ratings in NYC condo offering plans filed with the New York Attorney General, each cited to its plan page. Figures as of Nov 27, 2026.
Related: Mitsubishi or Daikin? The HVAC Brands in New NYC Condos · How NYC Condo Finishes Changed Since 2010