Do New NYC Condos Have ERVs? How Fresh Air Gets Into Your Apartment
Short answer: More and more do. 54% of the 61 NYC condo offering plans filed since 2025 that describe fresh air name an ERV (energy recovery ventilator), a small sample. Before 2014, 0% did. But "has an ERV" can mean three different things: a unit inside your apartment, a big shared unit on the roof, or one that only serves the hallways.
ERVs Went From Rare to Common
Every apartment needs fresh air. Offering plans say how it gets in, usually in the description of the building's systems. We read that description in 814 NYC condo plans. Most give one of three answers:
- Windows only. Rooms get fresh air from windows that open, as the building code allows. Bathrooms and kitchens without windows get exhaust fans.
- Central make-up air. A fan unit on the roof or a mechanical floor pushes outdoor air into the building, often into the hallways. In many towers it reaches each apartment through the gap under the front door.
- An ERV. A ventilator brings in outdoor air and sends stale air out at the same time, passing heat and moisture between the two streams so less energy is lost.
The ERV share has grown in every period: 0% of plans filed before 2014, 19% in 2014–2017, 24% in 2018–2021, 26% in 2022–2023, 37% in 2024 and 54% since 2025. Central make-up air shrank as ERVs grew, from 52% of plans filed in 2014–2017 to 15% since 2025. Windows-only plans held steadier: 28% of plans filed since 2025 still rely on them.
- 0%Before 2014
- 19%2014–2017
- 24%2018–2021
- 26%2022–2023
- 37%2024
- 54%2025–2026
Share of plans that describe how apartments get fresh air. 2026 is the year so far.
Condo Book Researchcondobooknyc.com/research/erv-fresh-air-nyc-condos
| Year plan was filed | Plans | ERV | Central make-up air | Windows only |
|---|---|---|---|---|
| Before 2014 | 207 | 0% | 31% | 68% |
| 2014–2017 | 133 | 19% | 52% | 26% |
| 2018–2021 | 240 | 24% | 38% | 36% |
| 2022–2023 | 114 | 26% | 35% | 39% |
| 2024 | 59 | 37% | 22% | 41% |
| 2025–2026 | 61 | 54% | 15% | 28% |
Share of plans that describe how apartments get fresh air, by the year the plan was first filed. HRVs and other methods make up the rest. 2026 is the year so far.
The plans rarely say why the developer chose an ERV. Some say it outright: one Brooklyn plan says its energy recovery units "are provided and designed to meet the NYC Energy Code." Tighter energy rules, sealed modern walls and windows, and all-electric heating all push the same way.
What an ERV Does, and How It Differs From an HRV
A new building is built tight to save energy, so little air leaks in on its own. Fresh air has to be brought in on purpose. The simplest way is a fan that pulls air in and another that pushes it out. In winter that means heating cold outdoor air from scratch; in summer, cooling and drying hot, humid air.
An ERV runs the outgoing and incoming air past each other through a core, without mixing them. In winter, the warm stale air warms the cold fresh air. In summer it works in reverse. An ERV also moves some moisture, which helps in a city with humid summers and dry winters.
An HRV (heat recovery ventilator) does the same thing for heat only, not moisture. HRVs are much rarer in these plans than ERVs. One example: 8 Saint Marks in Brooklyn specifies through-wall heat recovery ventilators in its bedrooms and living rooms.
Neither one is an air conditioner or a heater. Heat and cooling still come from the apartment's own system, such as a heat pump. Read how new NYC condos heat and cool for those systems.
Your Own ERV, a Shared One, or Only the Hallway
For each of the 169 plans that name an ERV, we read the plan sentence it came from to see where the ERV sits and what it serves:
- Your own ERV (20 plans): a ventilator inside each apartment, often in a ceiling or closet. 18 of these are buildings with under 30 apartments.
- A shared ERV that serves the apartments (36 plans): one or a few large units on the roof or a mechanical floor, with ducts running to every apartment.
- Common areas only (23 plans): the sentence ties the ERV only to corridors, the cellar, an amenity room or community space. The apartments themselves may rely on windows.
- Not stated (90 plans, the largest group): the sentence names an ERV but doesn't say what it serves. Read the full plan to find out.
Some examples:
- Rowan II in Queens gives each apartment its own ceiling-mounted ERV.
- 32 Walker in Manhattan equips each apartment with a dedicated ERV.
- 670 Union Street in Brooklyn specifies Zehnder ERVs in every apartment.
- 67 Irving Place in Manhattan gives each apartment an ERV that serves it alone.
- Lucent 33 in Queens supplies outdoor air to each apartment from four energy recovery units on the roof.
- 181 MacDougal Street in Manhattan ventilates every apartment through shared rooftop ERVs.
- The Morgan in Manhattan routes apartment exhaust through energy recovery units on the building's mechanical floors.
- 9 Chapel in Brooklyn feeds each apartment from one of two rooftop ERVs through shared duct risers.
- 144 Vanderbilt Avenue in Brooklyn uses both: rooftop ERVs plus small Lunos ERVs in the apartments.
Who owns the ERV matters. One inside your apartment is usually yours to maintain. A shared one on the roof is part of the building's equipment, and its upkeep comes out of common charges.
Brands in the plans
Only 30 of the ERV and HRV plans name a brand. Greenheck is named most often, in 5 plans. Zehnder and Lunos show up in plans that put an ERV in each apartment. AAON and CaptiveAire show up in packaged rooftop units.
| Greenheck | 5 |
|---|---|
| Zehnder | 4 |
| Panasonic | 4 |
| RenewAire | 4 |
| Energy Wall | 3 |
| Lunos | 2 |
| AAON | 1 |
| Innovent | 1 |
| Aldes | 1 |
| Fantech | 1 |
| NuTone | 1 |
| CaptiveAire | 1 |
| Petra | 1 |
| Thermotek | 1 |
Number of plans whose ERV or HRV sentence names the brand. Most plans don't name one.
Condo Book Researchcondobooknyc.com/research/erv-fresh-air-nyc-condos
Which Buildings Have ERVs
By borough. Among plans filed since 2022:
- Manhattan (73 plans): 45% ERV, 40% central make-up air, 14% windows only.
- Brooklyn (120 plans): 31% ERV, 18% central make-up air, 50% windows only.
- Queens (38 plans): 37% ERV, 29% central make-up air, 34% windows only.
By building size. Among plans filed since 2022, bigger buildings are more likely to name an ERV: 32% of 95 buildings under 10 apartments, 33% of 70 with 10 to 29, 44% of 52 with 30 to 99, and 53% of 17 with 100 or more. Windows-only drops the other way, from 49% in the smallest buildings to 18% in the largest.
By heating and cooling system. ERVs come with heat pumps, almost never with PTACs or radiators. 29% of 247 plans with VRF systems and 24% of 149 with split systems name an ERV. Of 27 plans with PTACs (through-wall units), 0% do; a PTAC can bring in some outdoor air itself. Of 96 plans with radiators, 1% do, and 93% rely on windows only.
By kitchen. All-electric kitchens and ERVs tend to come together. 60% of 52 plans with induction cooktops name an ERV, compared with 29% of 82 with standard electric cooktops and 17% of 536 with gas. Both tend to show up in newer, more energy-focused designs; the plans don't say one caused the other. See gas vs. induction stoves in new NYC condos.
How This Is Counted
We read how 814 NYC condo offering plans say apartments get fresh air: 169 name an ERV, 285 central make-up air, 348 windows only, and a few an HRV or something else. Plans are grouped by the year they were first filed with the New York Attorney General. Percentages are of plans that describe fresh air in each group. 2026 is the year so far.
Each plan gets one answer. A plan that names an ERV only for its corridors still counts as an ERV plan in the year, borough and size figures, which is why we read the sentences separately to see where each ERV sits. Plans can also change during construction, so the final building may differ from the plan.
Tips for Buyers
- Search the plan for "energy recovery" and "ERV." Read the sentence: does it serve "each unit," the apartments, or only "corridors"?
- If the ERV is in your apartment, ask where it is and how you reach the filter. ERV filters need cleaning or replacing on the schedule in the maker's manual, and a clogged one moves less air.
- If the ERV is shared, ask who changes its filters and whether that work is in the building's budget.
- An in-apartment ERV runs all the time. Ask to hear it running in a finished unit, especially if it's near a bedroom.
- An ERV isn't a range hood. Check separately how the kitchen hood vents.
- In a windows-only building, fresh air depends on you opening them. Think about street noise and pollen on the side the apartment faces.
Search "condos with ERV" on The Condo Book Project. See also how new NYC condos heat and cool and HVAC brands in NYC condos.
FAQ
Do new NYC condos have ERVs?
A growing share name one: 54% of the 61 NYC condo offering plans filed since 2025 that describe fresh air, compared with 0% of plans filed before 2014. Naming an ERV doesn't mean it serves your apartment: of all 169 plans that name one, only 56 clearly say it serves the apartments; 23 tie it only to common areas and the rest don't say.
What is an ERV in an apartment?
An energy recovery ventilator. It brings in fresh outdoor air and sends stale air out at the same time, passing heat and some moisture between the two streams so you aren't heating or cooling the fresh air from scratch.
What's the difference between an ERV and an HRV?
Both recover heat from outgoing air. An ERV also moves moisture; an HRV doesn't. ERVs are far more common in NYC condo plans.
Does every apartment in an ERV building have its own ERV?
No. Of 169 plans that name an ERV, 20 put one in each apartment and 36 use shared units that serve the apartments. In 23, the plan ties the ERV only to corridors or other common space.
Who changes the ERV filter in a condo?
It depends where the ERV is. One inside your apartment is usually the owner's to maintain; a shared rooftop unit is maintained by the building. Check the plan and ask the sponsor.
How do apartments without an ERV get fresh air?
Through windows that open, or through central make-up air: outdoor air pushed into the building by a fan unit, often into the hallways. 28% of plans filed since 2025 rely on windows only, and 15% on central make-up air.
Where do these figures come from?
From the fresh-air description in 814 NYC condo offering plans, grouped by the year each plan was first filed with the New York Attorney General. Figures as of Nov 27, 2026.